ts50

Medical Incinerator Model TS50

Considering Environmental Protection requirements and rules, almost all incinerator have secondary combustion chamber (after-burn, post-combustion), even if third combustion chamber. The secondary burner burn the Exhaust gas from primary combustion chamber, this technology make sure sufficient combustion, few black smoke and smell.

Product Description

The main body is one combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. Ignition element is external oil or gas burner. The burner can be running until waste burnout but for some waste like plastic, paper (sometime, mix coal with waste before feeding), they can combustion itself after Ignition. During combustion, burner has a fan itself for Oxygen supply and also protect burner avoid heat damage from combustion chamber. And, there a external fan blow air into combustion chamber. The Exhaust gas blow out after combustion.

Items/Model TS50(PLC) TS100(PLC)
Burn Rate 50 kg/hour 100 kg/hour
Feed Capacity 100kg 200 kg
Control Mode PLC PLC
Combustion Chamber 560L 1200L
Internal Dimensions 100x80x70cm 120x100x100cm
Secondary Chamber 280L 600L
Smoke Filter Chamber Yes Yes
Feed Mode Manual Manual
Voltage 220V 220V
Power 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 12.1–24 14–28
Gas Consumption (m3/hour) 9.9–26.1 10–32.2
Temperature Monitor Yes Yes
Temperature Protection Yes Yes
Oil Tank 100L 200L
Feed Door 70x55cm 80x60cm
Chimney 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec.
Gross Weight 4500kg 6000kg
External Dimensions 230x130x155cm 260x150x180cm