Combustion efficiency of ?99.0% Suitably designed pollution/emission control devices such as scrubbers, filters or electrostatic precipitator installed/retrofitted Double chambers, with combustion retention/ residency time of at least two seconds in the second chamber Feed rate/load capacity of ?1000kg and /or volume 1.5m Burn rate ?300kg/hour Attaining high temperature ?1200C Quick heat up times Constant run fan Diesel operated, with fuel consumption of ?12litres//hour Fitted with temperature controller/Monitor and thermostat control Constructed with heavy-duty material (e.g. anodished steel) with highly durable refractory cement lining (10cm or higher width preferable) High burn rates of at least 500kg per hour Easy installation and maintenance installation manual/DVD provided The desired Load capacity should be 1,000kg or 1.5 cu. m (volume), and Burn rate of between 300 500 kg/hour.
Incinerator plants
private and public sanitary and industrial establishments in our country, at aim to treat all kind of medical, hospital, veterinary and industrial wastes by Incineration Process. So, we’re interested with your Incinerator plants, and we’d like to get quotation and key features description of different capacities of your Incinerator plants, concerning: small models (5 – 25 kg/hr); medium models (25-50 kg/hr) and big models (50-100 kg/hr) and plus. 1. Burning Rate 50-120kg/hr 2. minimum operating temp 850degrees cel (primary combustion) 3. Max operating temp 1450 degrees cel (afterburner chamber) 4. Secondary Burning capacity compulsory 5. Density Insulation 20mm high 6. Refractory casting Minimum 65mm 7. Heavy duty refracting lining to withstand 1500 degrees cel. 8. Average burn out time: maximum 3.0 hrs 9. Fuel Type Diesel 10. Fuel Consumption in L/hr 11. Residence time in secondary chamber 2 sec 12. Residue ash post 100kg max. 3.8kg 13. Installation period maximum 7 days Capacity 100 kg/hr of waste containing up to 85% moisture The fuel tank will be located annexed to the dugout roof incinerator in a bund and have the following characteristics : Capacity: 1,200 liters Made of sheet steel for simple wall installation cubeto Output for ventilation diameter 1 ” Pressure gauge and filler cap Meter and level switch The incinerator has a consumption of 16.2 liters of diesel hour to burn waste generated operation 10 hours a week expected in two burning , so that autonomy will be 7.5 weeks . The reservoir will have an outlet and an inlet for return. Pipes for oil will drive the black steel pipe with longitudinal electric resistance welded 3/4 ” DN 20mm diameter . In the tank outlet pipe retainer debris filter , with aluminum body is placed , aluminum cup and stainless steel sieve with holes 100 microns in diameter . Two combustion chambers Two fully automatic, oil fired, pressure jet burners Panel board Diesel tank of capacity 250 It. with 2 diesel pipelines, filter and valve.
General wastes incinerators
General wastes produced on a daily basis include paper, plastic, organic materials, boxes, plastic containers, leaves, etc; Total waste produced per day: 10-12 tonnes; Hours of Operation: 10 hours a day; Fuel requirement: Diesel or waste oil preferred but LP gas will be considered; I also need a few some information on the installation i.e. spacing, building size, maintenance requirements, spare parts backing, PM inspections sheets, the number of employees required to operate the plant once operational etc. Other necessary information include the benefits of using the incinerator system, operating costs, power consumption, operation, waste disposal, PPE requirements, safety information, environmental concerns if any, disadvantages if any, etc. I will like to know your best prices for Grate Combustion Incinerator of sizes of between 700 tons/day to 200 tons/day. Also, state other available incinerators available and the cost of all the accompanying equipment for installation. The incinerating system should have the capacity to supply electricity, less harmful, not so technical to enable semi skilled operators and a few skilled operators, environmentally friendly and also not so expensive to acquire and maintain.
What’s Main Feature of Model A600 Pet Animal Incinerator
Main Feature of this model incinerator as below: 1, Primary and secondary and mix combustion chamber for pet animal and smoke burning. 2, smoke filter chamber for smoke filter 3, Stainless steel chimney 4, Italy original gas or oil burner, 2 sets total 5, Primary combustion chamber inner size is 130 x 70 x 65cm […]
Waste Incinerator Installation and Commissioning Services
Technicians from CLOVER are available to supervise customer’s skilled staff for installation, commissioning, train customer’s technical and production staff and help the staff to produce qualified end product. Clover’s engineers mission is operate or direct customer’s worker how to do. Local customer have to supply necessary equipment and local engineers or workers. Pease note that […]
Incinerator Fire Testing
Dispatch Incinerator for Africa
Three sets incinerator with 1oo kgs per hour capacity dispatch to Africa customer.
Mobile Containerized Incinerator
Mobile Containerized Incinerator, moveable for truck, buring rate upto 100kgs per hour. We design for end customer, we dispatch for better services. Model CA50 Feed Capacity Average 60 kgs per feed Burning Rate Average 70 kgs per hour Burning Time per Feed 1 hour Voltage 220V Power 0.7Kw Fuel Diesel oil Burner Italy Burner Feed […]
Waste Incinerator Fire Testing Before Shipping
Nanjing Clover Medical technology Co.,Ltd. is a leading waste incinerator manufacturer in China, the incinerator for hospital medical waste incineration, pets and animal cremation, other solid waste incineration treatment.
Dust Wet Scrubber System for Waste Incinerator
Clover supply optional dust wet scrubber system for waste incinerators. the main parts included wet cooling spray scrubber, wet dust filter and fog&waste separator. This system is valid for mid-large scale waste incinerator, model YD150,YD200,YD300,YD500,YD600. for small scale waste incinerator, supply dry scrubber(filter) chamber.
Small Scale Medical Waste Incinerators
Clover Incinerator supply medical waste incinerators with capacity 10kgs per hour to 500kgs per hour. The incinerator with dual/double combustion chamber and dry filter chamber, two fuel burner from Italy manufactured, hot sale model for small scale waste output, the capacity is 30kgs per hour and 50kgs per hour. We are famous small scale incinerator […]
Waste Incinerator vs Pet Cremator
a.) incinerator for waste. VS cremator for animals b.) incineration to be ash and clean it. VS cremation and collect ash into pet cremation urns. c.) waste stack disorderly.VS pet in chamber individual. d.) waste material complicated. VS pet is body. e.) waste incineration is public affairs. VS pet cremation is personal business more. f.) waste […]